<td id="44scu"><source id="44scu"></source></td>
<menu id="44scu"></menu><menu id="44scu"><strong id="44scu"></strong></menu>
  • Guangzhou Kingrise Enterprises Co., Ltd.
    All Products
    KE7303
    Portable Three Phase Standard Meter
    Accuracy : 0.05 / 0.1, Test method : terminal input or clamp CT input, test the error of three phase energy meters and feild electrical parameters of power grid

    Highlight

    2           Calibrate the error of all electricity energy meters, checking the constant of the energy meter

    2        Simultaneous checking of the primary meter and the secondary meter in the same loop, or simultaneously checking of the active power meter and reactive power meter inthe same loop

    2        Measure voltage, current, frequency, power, power factor and phase angle

    2        Simultaneous measure and display waveforms of three phase voltage and current

    2        Detectthe error change of the clamp automatically; ensure the accuracy stability ofthe clamp and the instrument in the long run.

    2        Measureratio of CT, VA burden of the metering loop from VT and CT secondary terminals.

    2        Allocate clamp of 20A, 100A, 500A, 1000A to directly measure the comprehensive error

    2        Measurethe 2nd – 51st harmonics of current and voltage

    2        Display vector diagram, judge the wiring right or wrong automatically

    2        Read the information of energy meter with barcode scanner (optional)

    2        Battery, test lead power or external power for choices

    2        Communicate with PC, download calibration data through USB flash disk, RS-232 or bluetooth 

    2        Firmware can be upgraded through removed disk by users themselves

    2        Save and browse the testing data, data storage quantity is 1000 group 

    Main specifications

     

    KE7303-0.05

    KE7303-0.1

    Voltage measurement

    Voltage range

    0V – 480V

    Accuracy

    ±0.05%

    ±0.1%

    Harmonics

    2nd- 51st

    Current measurement

    Current range

    Terminal input

    0.1A – 10A

    Clamp input

    5A、20A、100A、500A、1000A、2000A、3000A

    Accuracy

    Terminal input

    ±0.05%

    ±0.1%

    Clamp input

    ±0.2%5A)、±0.5% (others)

    Harmonics

    2nd- 51st

    Power measurement

    Active power

    Terminal input

    ±0.05%

    ±0.1%

    Clamp input

    ±0.2%5A)、±0.5% (others)

    Reactive power

    Terminal input

    ±0.05%

    ±0.1%

    Clamp input

    ±0.2%5A)、±0.5% (others)

    Energy measurement

    Active energy

    Terminal input

    ±0.05%

    ±0.1%

    Clamp input

    ±0.2%5A)、±0.5% (others)

    Reactive power

    Terminal input

    ±0.05%

    ±0.1%

    Clamp input

    ±0.2%5A)、±0.5% (others)

    Phase measurement

    Phase range

    0 -- 360°

    Accuracy

    ±0.05°

    ±0.1°

    Frequency measurement

    Frequency range

    45Hz – 65Hz

    Accuracy

    ±0.05Hz

    Pulse output

    High frequency outputCH

    3.6×107imp / kWh

    Low frequency outputCL

    3.6×104imp / kWh

    Pulse input

    Input channel

    2

    Input frequency

    Max. 100Hz

    Others

    Power supply

    Build-in rechargeable battery, external power supply, powered from the tested terminal

    Dimensions

    154mm×249mm×58mm

    Weight

    1.8kg

     

     